Analysis of Cooling System Abnormalities in Diesel Generators at MV. Meratus Kahayan

Authors

  • Jeremy Suryadharma Mangengke Program Studi Teknologi Rekayasa Permesinan Kapal, Fakultas Vokasi Pelayaran, Universitas Hang Tuah
  • Sugeng Marsudi Program Studi Teknologi Rekayasa Permesinan Kapal, Fakultas Vokasi Pelayaran, Universitas Hang Tuah

DOI:

https://doi.org/10.30649/japk.v14i2.108

Keywords:

abnormalities, diesel generator, cooling system

Abstract

The cooling system in a diesel generator is designed to maintain the engine temperature under ideal conditions during prolonged operation. If the cooling system experiences any abnormalities, it can negatively affect the performance of the diesel generator, resulting in suboptimal operation. However, these abnormalities can be addressed by understanding the system, identifying the causal factors, understanding the resulting impacts, and implementing appropriate solutions. This research utilizes a qualitative research method and employs fishbone analysis for data analysis. The findings will be presented descriptively to explain and provide detailed information based on the facts obtained during the research conducted on the ship. The conclusion of the study reveals that the abnormality in the diesel generator cooling system is primarily caused by inadequate flow of seawater as a cooling medium due to blockages in the sea chest filter and the fresh water cooler tube of the diesel generator. Moreover, the lack of coordination between the engine crew and the deck crew also contributes to these issues. As a result, the temperature of the coolant and the diesel generator oil increases. To address these issues, maintenance activities need to be performed on all components of the diesel generator cooling system according to the Planned Maintenance System (PMS).

References

Hasiah, H., Adnan, A., Musa, L., & Nurdin, A. (2019). Analisis Kinerja Diesel Generator Listrik di kapal MT. Fortune Glory XLI. Jurnal Venus, 7(14), 113-132.

Hidayat, S. (2019). Identifikasi Penyebab Naiknya Temperatur Air Tawar Pendingin Mesin Induk di MV. Armada Papua. 8-20. Karya Tulis.

Fadli, M. R. (2021). Memahami desain metode penelitian kualitatif. Humanika, Kajian Ilmiah Mata Kuliah Umum, 21(1), 33-54.

Asmoko, H. (2013). Teknik Ilustrasi Masalah-Fishbone Diagrams. Magelang: BPPK.

Galang, R. N. A. (2020). Sistem Pengoperasian dan Perawatan Air Pendingin Untuk Menunjang Mesin Induk di Tb. Alim II PT Kaltim Shipyard Samarinda. Karya Tulis.

Eko, R. (2019). Perawatan dan Perbaikan Sistem Pendingin Air Tawar Pada Mesin Induk di Kapal Motor. Mahkota Nusantara. Karya Tulis.

Sugiyono, (2017). Metode penelitian Pendidikan kuantitatif, kualitatif dan R&D. Jakarta: Alfabeta.

Downloads

Published

01-03-2024

How to Cite

Mangengke, J. S. ., & Marsudi, S. (2024). Analysis of Cooling System Abnormalities in Diesel Generators at MV. Meratus Kahayan. JURNAL APLIKASI PELAYARAN DAN KEPELABUHANAN, 14(2), 107–113. https://doi.org/10.30649/japk.v14i2.108